MT-PLC-12

Universal Pancake Load Cells

A tensile and compressive force transducer with a central threaded loading hub transfers axial tension and compression through radial shear webs into the outer bolted rim. Specify the complete fixture envelope before selecting a capacity.

Mechanical fit before procurement

Confirm the bolt circle and center thread.

1–500 kN family request envelope · Nickel-plated alloy steel or 17-4PH stainless steel, by configuration. UTM frames · servo cylinders · structural testing.

MT-PLC interface approval matrix. Listed force is the engineering enquiry range; dimensional release requires a capacity-specific drawing.
Model familyCapacity request · kN / lbfOuter Diameter (OD) · mm / inHeight (H) · cell / with baseCenter Thread · Metric / UNFOuter Bolt Circle · BCD & Hole CountNet Weight · kg / lbs
MT-PLC-121–500 kN
225–112,404 lbf
Project drawing requiredCell / base / button stack reviewed separatelyMetric / UNF / UN thread reviewBCD, count, bore, counterbore and pilot on released drawingSensor and full assembly mass confirmed before freight

For an installed replacement, supply the original drawing or measured envelope. Original manufacturer reference dimensions are labeled separately; they are not approved MT-PLC dimensions.

Download the original / proposed interface worksheet (CSV) ↓
Universal tension & compression: concept schematic of flange-supported axial force measurement; not a released product drawing

Original engineering illustration. Geometry and fasteners depend on the agreed configuration.

Capacity-specific acceptance

Define the load envelope behind the number.

  • Check fixture stiffness and thread engagement in both directions.
  • Specify rated force, peak force, force reversals and the test-machine uncertainty requirement.
  • Request tension/compression calibration points, bridge sensitivity, polarity and connector pinout.
Target non-linearity ±0.03% to ±0.05% FS is a configuration request, not a universal calibrated-system uncertainty. Request non-linearity, hysteresis, repeatability, creep and temperature effects as separate acceptance items.

Reference review: Interface 1210 / 1220 / 1240; HBK U10M. Original brand references do not establish fit, approval or affiliation.

Questions to settle before the fixture is frozen.

What are the thread engagement and reversing-load limits?

Check fixture stiffness and thread engagement in both directions.

Does the calibration cover both tension and compression?

Specify rated force, peak force, force reversals and the test-machine uncertainty requirement.

Which mating base reproduces the installed mounting boundary?

Request tension/compression calibration points, bridge sensitivity, polarity and connector pinout.

Packed mass and freight are itemized.

Compact models (1–25 kN): DHL Express parcel quotation with destination-specific transit estimates. Intermediate models (over 25 to under 50 kN): shipping assessed by packed mass. Heavy-capacity models (50–2,000 kN), including base assemblies: itemized DHL/FedEx heavy air freight on the formal Proforma Invoice. Availability, dispatch, customs and final freight are confirmed for the actual assembly and destination.

MT-PLC-12 · Configuration review

Build a bidirectional mechanical and electrical brief.

MT-PLC-12: requested range 1–500 kN (approximately 225–112,404 lbf). Exact configuration and rated performance require drawing approval.
DecisionReview input / acceptance
Force directionsRequest separate tension and compression points and the reversal/zero-return limits.
Metric / imperial interfaceSend M or UNF/UN size, pitch, tolerance, engagement and drawing revision.
Signal chainSpecify mV/V output, excitation, polarity, amplifier input and measurement bandwidth.

The engineering brief defines a request. The released datasheet and STEP file are supplied for the reviewed part and revision.

Published original-manufacturer reference

Read the original dimensions with the adapter variant.

The table below describes the original passive HBK U10M without a foot adapter. It is a reference for an installed-part review; MT-PLC fit remains unapproved until the complete interfaces and drawings are compared.

HBK B01444, revision 04 E00 14, 22 August 2025, printed page 3. Dimensions converted to inches from the stated millimetres.
Original rangeOD · mm / inBCD · mm / inCell height · mm / inOriginal center threadMounting bore ØS · mm
U10M 1.25 / 2.5 / 5 kN104.8 / 4.12688.9 / 3.50034.9 / 1.374M16×2-4H7; pattern/counterbores per source drawing
U10M 12.5 / 25 kN104.8 / 4.12688.9 / 3.50034.9 / 1.374M16×2-4H7; pattern/counterbores per source drawing
U10M 50 kN153.9 / 6.059130.3 / 5.13044.5 / 1.752M33×2-4H10.5; pattern/counterbores per source drawing
U10M 125 kN153.9 / 6.059130.3 / 5.13044.5 / 1.752M33×2-4H10.5; pattern/counterbores per source drawing
U10M 250 kN203.2 / 8.000165.1 / 6.50063.5 / 2.500M42×2-4H13.5; pattern/counterbores per source drawing
U10M 500 kN279 / 10.984229 / 9.01688.9 / 3.500M72×2-4H17; pattern/counterbores per source drawing

The foot adapter changes the assembly. Hole count, counterbores, thread engagement, overall height, output and connector must also be checked. A rounded family/frame label does not establish interchangeability.

Inspect the original HBK dimension drawing ↗
Define the measured result

Approve the calibration boundary with the fixture.

Specify whether the calibration covers the sensor alone or the sensor, mounting base, button, cable and amplifier as a system. Request traceability and uncertainty for the actual force range and direction.

Review calibration, standards and record requirements ↗

For a replacement, retain the full original model, both drawing revisions and the receiving instrument configuration. Machine verification is a separate acceptance step.

Request a calibration plan ↗
Engineering intake

Bring the load path.
We’ll review the fit.

Send your capacity, center thread and mounting envelope. Include the full original part number when replacing an installed sensor.

Request a dimensioned drawing, capacity-specific calibration plan and itemized hardware quotation before freezing the fixture.

inquiry@pancakeloadcells.com

CAD and test reports are supplied for the agreed configuration. No generic drawing is presented as an approved production part.

Include center-thread engagement, the base/button stack and flange pilots. Original-model dimensions and proposed MT-PLC dimensions are reviewed separately.

Required Hardware & Signal Options

Budget increments only. Engineering checks the selected sensor, integral/replaceable button, thread, amplifier protocol and calibration scope before quoting the assembly.

Compact models (1–25 kN): DHL Express parcel quotation with destination-specific transit estimates. Intermediate models (over 25 to under 50 kN): shipping assessed by packed mass. Heavy-capacity models (50–2,000 kN), including base assemblies: itemized DHL/FedEx heavy air freight on the formal Proforma Invoice. Availability, dispatch, customs and final freight are confirmed for the actual assembly and destination.

Your details are used to answer this request. Read the privacy notice.

Send the same engineering brief by email.

The email and copy actions include the values and options currently entered above. Keep this brief if your email app does not open.

View / select the complete brief