MT-PLC-1201

1201-Style Compression Low-Profile Load Cells

This high load capacity transducer is a compression-only low-profile load cell using a spherical load introduction surface to reduce sensitivity to small contact misalignments. The outer flange still needs a rigid, flat support and the specified fastener pattern.

Mechanical fit before procurement

Confirm the bolt circle and center thread.

2–1,800 kN family request envelope · High-strength alloy steel; finish and contact hardness by drawing. Servo press-fit · die closure · hydraulic press monitoring.

MT-PLC interface approval matrix. Listed force is the engineering enquiry range; dimensional release requires a capacity-specific drawing.
Model familyCapacity request · kN / lbfOuter Diameter (OD) · mm / inHeight (H) · cell / with baseCenter Thread · Metric / UNFOuter Bolt Circle · BCD & Hole CountNet Weight · kg / lbs
MT-PLC-12012–1,800 kN
450–404,656 lbf
Project drawing requiredCell / base / button stack reviewed separatelyIntegral contact / mating fixture reviewBCD, count, bore, counterbore and pilot on released drawingSensor and full assembly mass confirmed before freight

For an installed replacement, supply the original drawing or measured envelope. Original manufacturer reference dimensions are labeled separately; they are not approved MT-PLC dimensions.

Download the original / proposed interface worksheet (CSV) ↓
1201-style compression: concept schematic of flange-supported axial force measurement; not a released product drawing

Original engineering illustration. Geometry and fasteners depend on the agreed configuration.

Capacity-specific acceptance

Define the load envelope behind the number.

  • Identify the mating platen material, contact geometry and spherical button radius.
  • Submit the press force-time profile, impact peaks and machine stopping distance.
  • Verify clearance at peak deflection and include the base in the requested calibration setup.
Target non-linearity ±0.03% to ±0.05% FS is a configuration request, not a universal calibrated-system uncertainty. Request non-linearity, hysteresis, repeatability, creep and temperature effects as separate acceptance items.

Reference review: Interface 1201 family; exact installed model required. Original brand references do not establish fit, approval or affiliation.

Questions to settle before the fixture is frozen.

Is the load button integral or replaceable?

Identify the mating platen material, contact geometry and spherical button radius.

What is the total installed height with the mating base?

Submit the press force-time profile, impact peaks and machine stopping distance.

How should press impact and overload be specified?

Verify clearance at peak deflection and include the base in the requested calibration setup.

Packed mass and freight are itemized.

Compact models (1–25 kN): DHL Express parcel quotation with destination-specific transit estimates. Intermediate models (over 25 to under 50 kN): shipping assessed by packed mass. Heavy-capacity models (50–2,000 kN), including base assemblies: itemized DHL/FedEx heavy air freight on the formal Proforma Invoice. Availability, dispatch, customs and final freight are confirmed for the actual assembly and destination.

MT-PLC-1201 · Configuration review

Control contact geometry and the complete press stack.

MT-PLC-1201: requested range 2–1,800 kN (approximately 450–404,656 lbf). Exact configuration and rated performance require drawing approval.
DecisionReview input / acceptance
Spherical load introductionConfirm integral versus replaceable button, contact radius, platen material and surface condition.
Installed stackCompare cell-only, with-base and button-to-platen heights; keep deflection clearance.
Press dutySubmit normal peak, possible impact/overshoot and protection/stop behavior.

The engineering brief defines a request. The released datasheet and STEP file are supplied for the reviewed part and revision.

Define the measured result

Approve the calibration boundary with the fixture.

Specify whether the calibration covers the sensor alone or the sensor, mounting base, button, cable and amplifier as a system. Request traceability and uncertainty for the actual force range and direction.

Review calibration, standards and record requirements ↗

For a replacement, retain the full original model, both drawing revisions and the receiving instrument configuration. Machine verification is a separate acceptance step.

Request a calibration plan ↗
Engineering intake

Bring the load path.
We’ll review the fit.

Send your capacity, center thread and mounting envelope. Include the full original part number when replacing an installed sensor.

Request a dimensioned drawing, capacity-specific calibration plan and itemized hardware quotation before freezing the fixture.

inquiry@pancakeloadcells.com

CAD and test reports are supplied for the agreed configuration. No generic drawing is presented as an approved production part.

Include center-thread engagement, the base/button stack and flange pilots. Original-model dimensions and proposed MT-PLC dimensions are reviewed separately.

Required Hardware & Signal Options

Budget increments only. Engineering checks the selected sensor, integral/replaceable button, thread, amplifier protocol and calibration scope before quoting the assembly.

Compact models (1–25 kN): DHL Express parcel quotation with destination-specific transit estimates. Intermediate models (over 25 to under 50 kN): shipping assessed by packed mass. Heavy-capacity models (50–2,000 kN), including base assemblies: itemized DHL/FedEx heavy air freight on the formal Proforma Invoice. Availability, dispatch, customs and final freight are confirmed for the actual assembly and destination.

Your details are used to answer this request. Read the privacy notice.

Send the same engineering brief by email.

The email and copy actions include the values and options currently entered above. Keep this brief if your email app does not open.

View / select the complete brief

Project inbox: inquiry@pancakeloadcells.com.