MT-PLC-3201

3201-Style Stainless Steel Pancake Load Cells

A stainless steel spoke-type load cell brings the low-profile flange architecture to corrosive and wet installations. Seal performance depends on the finished assembly, including the cable exit and connector.

Mechanical fit before procurement

Confirm the bolt circle and center thread.

2.5–1,000 kN family request envelope · 17-4PH precipitation-hardened stainless steel. Outdoor test rigs · reactor vessels · humid process equipment.

MT-PLC interface approval matrix. Listed force is the engineering enquiry range; dimensional release requires a capacity-specific drawing.
Model familyCapacity request · kN / lbfOuter Diameter (OD) · mm / inHeight (H) · cell / with baseCenter Thread · Metric / UNFOuter Bolt Circle · BCD & Hole CountNet Weight · kg / lbs
MT-PLC-32012.5–1,000 kN
562–224,809 lbf
Project drawing requiredCell / base / button stack reviewed separatelyMetric / imperial loading interface reviewBCD, count, bore, counterbore and pilot on released drawingSensor and full assembly mass confirmed before freight

For an installed replacement, supply the original drawing or measured envelope. Original manufacturer reference dimensions are labeled separately; they are not approved MT-PLC dimensions.

Download the original / proposed interface worksheet (CSV) ↓
3201-style stainless steel: concept schematic of flange-supported axial force measurement; not a released product drawing

Original engineering illustration. Geometry and fasteners depend on the agreed configuration.

Capacity-specific acceptance

Define the load envelope behind the number.

  • Specify chemical species, concentration, temperature, washdown or immersion duration.
  • Request the assembly-specific sealing report; an IP68 design request is not a universal immersion rating.
  • For vessels, submit support count, tare, thermal expansion and piping restraint loads. Hazardous-area approval requires separate evidence.
Target non-linearity ±0.03% to ±0.05% FS is a configuration request, not a universal calibrated-system uncertainty. Request non-linearity, hysteresis, repeatability, creep and temperature effects as separate acceptance items.

Reference review: Interface 3200 / 3201; Flintec only after exact model review. Original brand references do not establish fit, approval or affiliation.

Questions to settle before the fixture is frozen.

Does the IP test include the selected connector?

Specify chemical species, concentration, temperature, washdown or immersion duration.

Is chemical exposure compatible with the cable and seal?

Request the assembly-specific sealing report; an IP68 design request is not a universal immersion rating.

Does the installation need hazardous-area approval?

For vessels, submit support count, tare, thermal expansion and piping restraint loads. Hazardous-area approval requires separate evidence.

Packed mass and freight are itemized.

Compact models (1–25 kN): DHL Express parcel quotation with destination-specific transit estimates. Intermediate models (over 25 to under 50 kN): shipping assessed by packed mass. Heavy-capacity models (50–2,000 kN), including base assemblies: itemized DHL/FedEx heavy air freight on the formal Proforma Invoice. Availability, dispatch, customs and final freight are confirmed for the actual assembly and destination.

MT-PLC-3201 · Configuration review

Qualify the sealed assembly for the actual exposure.

MT-PLC-3201: requested range 2.5–1,000 kN (approximately 562–224,809 lbf). Exact configuration and rated performance require drawing approval.
DecisionReview input / acceptance
17-4PH assembly requestIdentify material condition, medium, concentration, temperature and exposure duration.
Seal boundaryReview connector mated/unmated state, cable exit, washdown or immersion conditions.
Process-vessel supportsInclude tare, working load, support count, piping restraint and thermal movement.

The engineering brief defines a request. The released datasheet and STEP file are supplied for the reviewed part and revision.

Define the measured result

Approve the calibration boundary with the fixture.

Specify whether the calibration covers the sensor alone or the sensor, mounting base, button, cable and amplifier as a system. Request traceability and uncertainty for the actual force range and direction.

Review calibration, standards and record requirements ↗

For a replacement, retain the full original model, both drawing revisions and the receiving instrument configuration. Machine verification is a separate acceptance step.

Request a calibration plan ↗
Engineering intake

Bring the load path.
We’ll review the fit.

Send your capacity, center thread and mounting envelope. Include the full original part number when replacing an installed sensor.

Request a dimensioned drawing, capacity-specific calibration plan and itemized hardware quotation before freezing the fixture.

inquiry@pancakeloadcells.com

CAD and test reports are supplied for the agreed configuration. No generic drawing is presented as an approved production part.

Include center-thread engagement, the base/button stack and flange pilots. Original-model dimensions and proposed MT-PLC dimensions are reviewed separately.

Required Hardware & Signal Options

Budget increments only. Engineering checks the selected sensor, integral/replaceable button, thread, amplifier protocol and calibration scope before quoting the assembly.

Compact models (1–25 kN): DHL Express parcel quotation with destination-specific transit estimates. Intermediate models (over 25 to under 50 kN): shipping assessed by packed mass. Heavy-capacity models (50–2,000 kN), including base assemblies: itemized DHL/FedEx heavy air freight on the formal Proforma Invoice. Availability, dispatch, customs and final freight are confirmed for the actual assembly and destination.

Your details are used to answer this request. Read the privacy notice.

Send the same engineering brief by email.

The email and copy actions include the values and options currently entered above. Keep this brief if your email app does not open.

View / select the complete brief

Project inbox: inquiry@pancakeloadcells.com.